標準物質一站式采購平臺
Cyanide QC CRM
Catalog Number:QCI-015
Solvent: Water/NaOH
Hazards: Irritant
Analyte:Cyanid
Study Mean (mg/kg) 0.398
Gravimetric Concentration(mg/kg) 0.404±0.011
Acceptance Limits(mg/kg) 0.303-0.505
This quality control sample was manufactured by NSI Lab Solutions fllowing quality procedures meeting the requirements of ISO 9001,ISO 17025, and ISO 17034. Acceptance limits are set at current NELAC standards. The study mean is set at the mean of an interlaboratory proficiency testing study with outier rejectin. This sample is intended to be used to validate analytical methods, for detection limit studies, and analyst proficiency testing.
Storage & Instructions For Use
The unopened ampule can be stored at room temperature (15- 30°C). Keep away from light.
Mix the contents of the ampule by inversion before opening.
Filla 1000 mL Class A volumetric flask with 900 mL of organic free reagent water.
Adjust the alkalinity of the reagent water to pH.12 with 1-2 mL of 50% NaOH.
Open the ampule and pipet exactly 10.0 mL of the concentrate into the flask.
Bring the flask to volume with reagent water and mix well.
This represents the sample for analysis.
Traceability Information
Analyte Source Materials: The highest purity analyte source materials are used in the manufacture of this CRM. Analyte source material purity and associated uncertainty has been analytically venified against appropriate NIST SRMs, where available.
Balance: All analytical balances are calibrated on a semiannual basis by an ISO 17025 accredited calibration laboratory and are traceable to NIST. Traceable Calibration Certificate available upon request.
All balances are checked daily by an in-house standard operating procedure. The weights used for this daily verification are calibrated annually by an IsO 17025 accredited calibration laboratory and are certified traceable to NIST. Cerificate of Calibration and Traceability available upon request.
Thermometer: All thermometers are NIST traceable through thermometers that are calibrated annually by an ISO 17025 accredited calibration laboratory.
Glassware:All glassware used in the manufacture of our samples is Class A. An in-house standard operating procedure is used to verify all glassware prior to it being placed into service. Volumetric pipetors are calibrated every four months by an ISO 17025 accredited calibration laboratory.
Uncertainty
The±uncertainty associated with the certifed concentration is the expanded uncertainty at 95% confidence interval (CI) with K=2. This expanded uncertainty incorporates contributions from manufacturing, homogeneity, and stability.
Homogeneity
This quality control CRM was thoroughly mixed in production. Batch homogeneity was established through analyses of samples chosen at random.
Stability/Expiration
The stability of this quality control CRM is based on short-term and long-term monitoring of the certified cncentration. The expiration date is guaranteed to be valid from the manufacture date and is based on results of long-term monitoring. Guarantee is applicable to the unopened ampule.
注:以上信息僅供參考,以產品附帶證書為準。
水質總氰化物(標樣)
編號:BWZ6672-2016C CAS號:151-50-8 規(guī)格:20mL 濃度:0.40μg/mL
水質總氰化物(標樣)
編號:BWZ6672-2016A CAS號:143-33-9 規(guī)格:20mL 濃度:2.00μg/mL
水質總氰化物(標樣)
編號:BWZ6672-2016B CAS號:143-33-9 規(guī)格:20mL 濃度:0.52μg/mL
水質總氰化物(標樣)
編號:BWZ6672-2016D CAS號:143-33-9 規(guī)格:20mL 濃度:46.1μg/L
海水中氰化物(標樣)
編號:BWZ7553-2016 CAS號:143-33-9 規(guī)格:20mL 濃度:0.45μg/mL
通話對您免費,請放心接聽
溫馨提示:
1.手機直接輸入,座機前請加區(qū)號 如13164239859,010-58103778
2.我們將根據您提供的電話號碼,立即回電,請注意接聽
3.因為您是被叫方,通話對您免費,請放心接聽